<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-24 22-26-46
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 56 dBuV VOLTAGE
Pilot RDS Phase Difference
7.1 kHz 3.5 kHz 22 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
27 kHz 73 kHz 7000 24,7857
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
7,7 dBr 8,28 dBr 8,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 22:26, 24.12.2024
RT
"VOLTAGE - Dance music "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (56 dBuV) Max at: 73 kHz MIN: 27 kHz % above 75 kHz: 24,7857 Acquired: 2024/12/24 22:25:42 Total samples: 7000 Equivalent time: 0:05:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 8,7 dBr MIN: 7,7 dBr AVE: 8,28 dBr % above 10,0 dBr: 0,0 Last value: 8,2 dBr (2024/12/24 22:25:42) Station: 96.90 MHz, signal: 4/5 (56 dBuV) 22:21 22:22 22:23 22:24 22:25 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality